Shopping Cart

Honeywell Analytics Sensepoint XCD Gas Detector, 4 to 20 mA output, painted LM25, includes catalytic sensor cartridge 0 to 100%LEL- SPXCDALMFX

Brand:Honeywell

For pricing and availability, please send an email to info@industrytechstore.com

Gas Detector

 

Brand: Honeywell

Model: SPXCDALMFX

 

Description

 

XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted Marine Grade Al, includes catalytic sensor cartridge 0 to 100% LEL, user-selectable FSD between 20% and 100% LEL (10% LEL resolution), and includes nylon weather protection. 

Technical Data 


 

 

 

 

 

 

Use

3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.

Input Voltage Range

16 to 32VDC (24VDC nominal)

Max Power Consumption

Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC

Current Output

Sink or source

 

 

 

 

 

Relays

3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized

Communication

RS485, MODBUS RTU

 

 

 

 