Description
System
Pro M compact S200P miniature circuit breakers are current-limiting. They have
two different tripping mechanisms: the delayed thermal tripping mechanism for
overload protection and the electromechanics tripping mechanism for short
circuit protection. They are available in different characteristics
(B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to
25 kA at 230/400 V AC), and rated currents (up to 63A). All MCBs of the product
range S200P comply with IEC/EN 60898-1, IEC/EN 609 47-2, UL1077, and CSA 22.2
No. 235, allowing the use for residential, commercial, and industrial
applications. Bottom-fitting auxiliary contact can be mounted on S200P to save
50% space.
Technical
Details
Standards |
CSA
22.2 No. 235 IEC/EN
60898-1 IEC/EN
60947-2 UL
1077 |
Tripping
Characteristic |
C |
Rated
Operational Voltage |
acc.
to IEC 60898-1 400 V AC acc.
to IEC 60898-1 400 V acc.
to IEC 60947-2 400 V AC |
Operational
Voltage |
Maximum
(Incl. Tolerance) 125 V DC Maximum
(Incl. Tolerance) 440 V AC Minimum
12 V AC Minimum
12 V DC |
Rated
Insulation Voltage (Ui) |
acc.
to IEC/EN 60664-1 440 V |
Rated
Impulse Withstand Voltage (Uimp) |
4
kV at
2000 m 5 kV at
Sea Level 6.2 kV |
Dielectric
Test Voltage |
50/60
Hz, 1 min: 2 kV |
Input
Voltage Type |
AC/DC |
Rated
Short-Circuit Capacity |
(AC)
25 kA (230
V AC) 25 kA (400
V AC) 25 kA (400
V) 25 kA |
Rated
Ultimate Short-Circuit Breaking Capacity (Icu) |
(230
V AC) 25 kA (400
V AC) 25 kA (400
V) 25 kA |
Ambient
Air Temperature |
Operation
-25 ... +55 °C Storage
-40 ... +70 °C |
Degree
of Protection |
IP20 IP40 Enclosure
with Cover IP40 |
System pro M compact
S200P miniature circuit breakers are current limiting. They have two different
tripping mechanisms, the delayed thermal tripping mechanism for overload
protection and the electromechanics tripping mechanism for short circuit
protection. They are available in different characteristics (B,C,D,K,Z),
configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 25 kA at
230/400 V AC) and rated currents (up to 63A). All MCBs of the product range
S200P comply with IEC/EN 60898-1, IEC/EN 609 47-2, UL1077 and CSA 22.2 No. 235,
allowing the use for residential, commercial and industrial applications.
Bottom-fitting auxiliary contact can be mounted on S200P to save 50% space.